{"id":24927,"date":"2020-05-05T13:15:38","date_gmt":"2020-05-05T11:15:38","guid":{"rendered":"https:\/\/www.eli-beams.eu\/?page_id=24927"},"modified":"2021-01-26T16:53:58","modified_gmt":"2021-01-26T15:53:58","slug":"biolab","status":"publish","type":"page","link":"https:\/\/www.eli-beams.eu\/facility\/laboratories-workshops\/laboratories\/biolab\/","title":{"rendered":"BioLab"},"content":{"rendered":"<p><img loading=\"lazy\" class=\"alignnone size-medium wp-image-25449\" src=\"https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3699-1-300x225.jpg\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3699-1-300x225.jpg 300w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3699-1-1024x768.jpg 1024w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3699-1-768x576.jpg 768w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3699-1-1536x1152.jpg 1536w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3699-1-2048x1536.jpg 2048w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3699-1-400x300.jpg 400w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> <img loading=\"lazy\" class=\"alignnone size-medium wp-image-25451\" src=\"https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3698-300x225.jpg\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3698-300x225.jpg 300w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3698-1024x768.jpg 1024w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3698-768x576.jpg 768w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3698-1536x1152.jpg 1536w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3698-2048x1536.jpg 2048w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3698-400x300.jpg 400w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><img loading=\"lazy\" class=\"alignnone wp-image-24628 size-full\" src=\"https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/04\/ELIBIO1.jpg\" alt=\"\" width=\"1024\" height=\"721\" srcset=\"https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/04\/ELIBIO1.jpg 1024w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/04\/ELIBIO1-300x211.jpg 300w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/04\/ELIBIO1-768x541.jpg 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p><strong>Aside from the instrumentation utilized for research activities on femtosecond laser spectroscopy which is described elsewhere, the BioLab is equipped with the following instrumentation:<\/strong><\/p>\n<ul>\n<li>Sample preparation\n<ul>\n<li>Cell culture\n<ul>\n<li>Incubator POL-EKO CLN53, 50l capacity, up to 100<sup>o<\/sup>C<\/li>\n<li>Refrigerated incubating orbital shakers\n<ul>\n<li>Labwit ZWYR-240 (cap. 4 x 2l bottles)<\/li>\n<li>2x Labwit ZWYC-290A (cap. 4 x 5l bottles)<\/li>\n<\/ul>\n<\/li>\n<li>Protein purification\n<ul>\n<li>Centrifuges\n<ul>\n<li>Large volume &#8211; HIMAC CR22N (4l up to 15 300g)<\/li>\n<li>Ultra &#8211; Beckman Coulter Optima X-PN80 (up to 210 000g)<\/li>\n<li>Benchtop \u2013 Medium volume (15 ml) \u2013 Hermle Z 326 K<\/li>\n<li>Microliter refrigerated \u2013 Hermle Z 216 MK<\/li>\n<li>Microliter x2 \u2013 Hermle Z216 M<\/li>\n<\/ul>\n<\/li>\n<li>Homogenizer (Avestin EmulsiFlex C3)<\/li>\n<li>Sonicator (QSonica 700)<\/li>\n<li>FPLC &#8211; (BIORAD NGC Quest\u2122 10 Plus)<\/li>\n<\/ul>\n<\/li>\n<li>Molecular Genetics\n<ul>\n<li>Benchmark H5000-HC-E shaker (20 x 1.5 ml, 6 x 50 ml)<\/li>\n<li>PCR cycler \u2013 Analytic Jena TAdvanced Twin 48 G<\/li>\n<li>Electrophoresis equipment (power supply, tanks, etc.)<\/li>\n<li>Gel and Blot Imager (Bio-Rad Chemidoc MP)<\/li>\n<\/ul>\n<\/li>\n<li>Crystallisation\n<ul>\n<li>Incubators for crystal growth (Schoeller PHCBi MIR-554)<\/li>\n<li>refrigerated thermomixer for 15 ml vials<\/li>\n<\/ul>\n<\/li>\n<li>Development of sample delivery methods\n<ul>\n<li>Differential mobility analyzer \/ Particle sizer (TSI)<\/li>\n<li>Laser for injector tests (Litron Nano PIV)<\/li>\n<li>Camera for Mie scattering<\/li>\n<li>Nanoparticle tracking analyzer (Malvern Nanosight)<\/li>\n<li>Pressure systems, liquid jet injectors, aerosol generation equipment (electrospray, GDVN)<\/li>\n<\/ul>\n<\/li>\n<li>Sample characterisation\n<ul>\n<li>Spectroscopy\n<ul>\n<li>Time-correlated single photon counting system (Picoquant)<\/li>\n<li>FTIR Spectrometer (Shimadzu IRSpirit 7800-350 cm-1)<\/li>\n<li>double-beam UV-VIS-NIR absorption spectrophotometer (JASCO V-770, 190-2700 nm)<\/li>\n<\/ul>\n<\/li>\n<li>Microscopy\n<ul>\n<li>Fluorescence microscope (Zeiss AxioImager Z2)<\/li>\n<li>Inverted microscope (Zeiss AxioObserver)<\/li>\n<li>High-end polarizing stereomicroscope (Zeiss Discovery V-20)<\/li>\n<li>Environmental scanning electron microscope\n<ul>\n<li>Thermo Scientific \/ FEI Quattro S\n<ul>\n<li>detectors: ETD, GSED, DBS, STEM<\/li>\n<li>wet-STEM cold stage<\/li>\n<\/ul>\n<\/li>\n<li>Quorum Cryo-SEM PP3010T preparation system\n<ul>\n<li>Freezing and drying samples<\/li>\n<li>Platinum plasma sputtering<\/li>\n<li>In-chamber cryo-stage<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" class=\"alignnone wp-image-25439 size-medium\" src=\"https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3721-300x225.jpg\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3721-300x225.jpg 300w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3721-1024x768.jpg 1024w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3721-768x576.jpg 768w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3721-1536x1152.jpg 1536w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3721-2048x1536.jpg 2048w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3721-400x300.jpg 400w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> <img loading=\"lazy\" class=\"alignnone size-medium wp-image-25441\" src=\"https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3720-300x225.jpg\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3720-300x225.jpg 300w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3720-1024x768.jpg 1024w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3720-768x576.jpg 768w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3720-1536x1152.jpg 1536w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3720-2048x1536.jpg 2048w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3720-400x300.jpg 400w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-medium wp-image-25443\" src=\"https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3716-300x225.jpg\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3716-300x225.jpg 300w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3716-1024x768.jpg 1024w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3716-768x576.jpg 768w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3716-1536x1152.jpg 1536w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3716-2048x1536.jpg 2048w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3716-400x300.jpg 400w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> <img loading=\"lazy\" class=\"alignnone size-medium wp-image-25445\" src=\"https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3712-300x225.jpg\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3712-300x225.jpg 300w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3712-1024x768.jpg 1024w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3712-768x576.jpg 768w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3712-1536x1152.jpg 1536w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3712-2048x1536.jpg 2048w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3712-400x300.jpg 400w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<h4><img loading=\"lazy\" class=\"alignnone size-medium wp-image-25447\" src=\"https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3705-225x300.jpg\" alt=\"\" width=\"225\" height=\"300\" srcset=\"https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3705-225x300.jpg 225w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3705-768x1024.jpg 768w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3705-1152x1536.jpg 1152w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3705-1536x2048.jpg 1536w, https:\/\/www.eli-beams.eu\/wp-content\/uploads\/2020\/06\/IMG-3705-scaled.jpg 1920w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><\/h4>\n<p><strong>Biolab\u00a0 3D TOUR<\/strong><\/p>\n<p><iframe loading=\"lazy\" src=\"https:\/\/my.matterport.com\/show\/?m=QY31K7mKvo7\" width=\"853\" height=\"480\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Aside from the instrumentation utilized for research activities on femtosecond laser spectroscopy which is described elsewhere, the BioLab is equipped&#8230;<\/p>\n","protected":false},"author":1,"featured_media":25437,"parent":24929,"menu_order":338,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/www.eli-beams.eu\/wp-json\/wp\/v2\/pages\/24927"}],"collection":[{"href":"https:\/\/www.eli-beams.eu\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.eli-beams.eu\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.eli-beams.eu\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.eli-beams.eu\/wp-json\/wp\/v2\/comments?post=24927"}],"version-history":[{"count":0,"href":"https:\/\/www.eli-beams.eu\/wp-json\/wp\/v2\/pages\/24927\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.eli-beams.eu\/wp-json\/wp\/v2\/pages\/24929"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.eli-beams.eu\/wp-json\/wp\/v2\/media\/25437"}],"wp:attachment":[{"href":"https:\/\/www.eli-beams.eu\/wp-json\/wp\/v2\/media?parent=24927"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}